CRD LF-C
Clean Room Design Laminar flow booths provide product protection for work areas of various sizes, such as general process technology and sterile filling of pharmaceutical and food products.
Product protection is ensured by controlled airflow. A clean and laminar air flows vertically into the working area of the booth and is discharged near the floor.
Dimensions on request
Features:
- AISI 304 stainless steel construction
- Perforated ceiling and perforated grille for air outlet
- EC fans of high efficiency and low sound level, with adjustable speed
- Housing with HEPA filter
- Laminar air flow system
- Adjustable airflow speed: 0.25-0.45 m/s
- LED illumination
- Integrated control system
- Suspension from ceiling or floor standing unit
- Flow restriction by PVC curtain, polycarbonate glass or closed wall elements
Basic options:
- Prefilter G-4 and HEPA filter H14
- Pressure gauge
- LED illuminated
- Acoustic and visual alarm
- Safety button
- Working hours counter
- Antistatic PVC curtain
Additional options:
- Double pressure gauge with differential display: filter clogging control
- Filter clogging alarm
- UV lamp
- Counter of working hours of the UV lamp